Skip to content
CovaSyn
Intro call

Analytics · Impurities

“A peak has appeared above the identification threshold, and we do not know what it is.”

Identify an unknown impurity by LC-MS

An unknown peak above the identification threshold holds up release, a stability study or a submission. CovaSyn interprets your LC-MS data and, where available, NMR data, proposes structures that fit the API and the process, and then assesses their mutagenic potential under ICH M7. Your expert reviews and approves the report.

When you need this

  • A new peak appears in the stability study or after a process change.
  • The impurity profile of a generic differs from the reference product.
  • Mass balance does not close in forced degradation, and degradation products are missing.
  • The authority asks for the structure and classification of an impurity so far only listed by relative retention time.

What it costs when the case stays open

  • Batch release is on hold as long as the peak has no name.
  • Without a structure there is no ICH M7 classification, and the submission waits.
  • Isolating and elucidating by hand ties up your best people for weeks.

What you get

  • Structure candidates with reasoning

    Molecular formula from accurate mass and isotope pattern, fragment annotation and a ranked list of plausible structures derived from API, synthesis route and degradation pathways.

  • Impurity profile and mass balance

    Assignment of peaks to process impurities or degradation products and a check whether the mass balance of the stressed samples closes plausibly.

  • ICH M7 classification

    For each candidate, structural alerts, a mutagenicity prediction with applicability domain and a proposed ICH M7 class.

  • Report for review and approval

    Data, conclusions and open points are in the report, including the measurement that would finally confirm a structure.

From an open case to a approved report

  • 1. Discuss the case

    30 minutes on Microsoft Teams about the compound, the question and the data. Afterwards you know whether we take on the case and which data we need.

  • 2. Hand over the data

    Raw data and context, such as spectra, chromatograms, stability tables and the specification. The report typically arrives within 5 working days once we have your complete data.

  • 3. Review and release

    The report states its data basis, calculation path and limits. Review and release happen on your side under your quality system.

What we evaluate for this

Every number is computed and reproducible, predictions state their uncertainty. Every evaluation is documented with its input data and reasoning so your expert can review and sign it off.

  • MS: unknown peak resolved

    Unknown peak analysis, molecular formula, isotope pattern, fragment annotation and neutral losses, impurity profiling, degradation product prediction, forced degradation and mass balance.

  • NMR: structure confirmed

    Structure confirmation from NMR data of an isolated or enriched fraction, candidate verification and impurity analysis.

  • Toxicology: ICH M7 classification

    ICH M7 classification, structural alerts, applicability domain check and comparison with similar structures that have already been assessed.

Who it is for

For analytical, CMC and regulatory affairs teams at contract labs, CDMOs and generics manufacturers, wherever an unknown impurity holds up a release or a submission.

What the computation does not replace

  • Mass spectrometry alone often cannot distinguish positional isomers. A structure only counts as confirmed once NMR data or a reference standard support it.
  • ICH M7 classification draws on literature and database data plus two (Q)SAR predictions and needs review by a qualified expert; we state explicitly when a structure lies outside the applicability domain.
  • A prediction does not replace a measurement. Without fragment spectra or accurate masses the conclusion stays correspondingly preliminary.

Common questions

How do I identify an unknown impurity by LC-MS?

First determine the molecular formula from accurate mass and isotope pattern, then derive fragments and neutral losses from the MS/MS spectrum and match them against the API, the synthesis route and known degradation pathways. CovaSyn works through these steps systematically and delivers a ranked list of candidates with reasoning.

Who can identify an unknown impurity for us?

We do. In the initial call we go through the peak, substance and data and agree on scope. The report typically arrives within 5 working days once we have your complete data.

When does an impurity have to be identified?

For drug substances and drug products, ICH Q3A and Q3B set reporting, identification and qualification thresholds that depend on the maximum daily dose. Potentially mutagenic impurities additionally fall under ICH M7 with much lower limits. CovaSyn supports identification and classification; which threshold applies to your product is decided by your regulatory expert.

What should I do if mass balance does not close in forced degradation?

Common causes are degradation products without a chromophore, volatile or non-eluting products and different response factors. CovaSyn predicts likely degradation products, searches for them in your MS data and shows where the missing mass most likely is.

How is an identified impurity classified under ICH M7?

First, existing mutagenicity and carcinogenicity data are searched. If there are none, the structure is assessed with two complementary (Q)SAR methodologies, one expert rule-based and one statistical, followed by expert review. CovaSyn provides alerts, prediction and applicability domain as the basis; your qualified expert confirms the classification.

Free PDF

Results you can rely on

Our beginner's guide for chemistry, pharma and biotech: how to tell an estimate from a calculation, seven questions to ask of every result and six questions to ask every provider. 8 pages.

Get the guide

Next step

Tell us about your unknown peak.

30 minutes on Microsoft Teams with the CovaSyn team. If it is not a fit, we will say so.