Analytics · Impurities
“A peak has appeared above the identification threshold, and we do not know what it is.”
Identify an unknown impurity by LC-MS
An unknown peak above the identification threshold holds up release, a stability study or a submission. CovaSyn interprets your LC-MS data and, where available, NMR data, proposes structures that fit the API and the process, and then assesses their mutagenic potential under ICH M7. Your expert reviews and approves the report.
When you need this
- A new peak appears in the stability study or after a process change.
- The impurity profile of a generic differs from the reference product.
- Mass balance does not close in forced degradation, and degradation products are missing.
- The authority asks for the structure and classification of an impurity so far only listed by relative retention time.
What it costs when the case stays open
- Batch release is on hold as long as the peak has no name.
- Without a structure there is no ICH M7 classification, and the submission waits.
- Isolating and elucidating by hand ties up your best people for weeks.
What you get
Structure candidates with reasoning
Molecular formula from accurate mass and isotope pattern, fragment annotation and a ranked list of plausible structures derived from API, synthesis route and degradation pathways.
Impurity profile and mass balance
Assignment of peaks to process impurities or degradation products and a check whether the mass balance of the stressed samples closes plausibly.
ICH M7 classification
For each candidate, structural alerts, a mutagenicity prediction with applicability domain and a proposed ICH M7 class.
Report for review and approval
Data, conclusions and open points are in the report, including the measurement that would finally confirm a structure.
From an open case to a approved report
1. Discuss the case
30 minutes on Microsoft Teams about the compound, the question and the data. Afterwards you know whether we take on the case and which data we need.
2. Hand over the data
Raw data and context, such as spectra, chromatograms, stability tables and the specification. The report typically arrives within 5 working days once we have your complete data.
3. Review and release
The report states its data basis, calculation path and limits. Review and release happen on your side under your quality system.
What we evaluate for this
Every number is computed and reproducible, predictions state their uncertainty. Every evaluation is documented with its input data and reasoning so your expert can review and sign it off.
MS: unknown peak resolved
Unknown peak analysis, molecular formula, isotope pattern, fragment annotation and neutral losses, impurity profiling, degradation product prediction, forced degradation and mass balance.
NMR: structure confirmed
Structure confirmation from NMR data of an isolated or enriched fraction, candidate verification and impurity analysis.
Toxicology: ICH M7 classification
ICH M7 classification, structural alerts, applicability domain check and comparison with similar structures that have already been assessed.
Who it is for
For analytical, CMC and regulatory affairs teams at contract labs, CDMOs and generics manufacturers, wherever an unknown impurity holds up a release or a submission.
What the computation does not replace
- Mass spectrometry alone often cannot distinguish positional isomers. A structure only counts as confirmed once NMR data or a reference standard support it.
- ICH M7 classification draws on literature and database data plus two (Q)SAR predictions and needs review by a qualified expert; we state explicitly when a structure lies outside the applicability domain.
- A prediction does not replace a measurement. Without fragment spectra or accurate masses the conclusion stays correspondingly preliminary.
Read on
Unknown Impurity Identification by LC-MS/MS
Unknown impurity identification by LC-MS: formula from accurate mass, RDBE, isotope pattern and MS/MS fragment logic, with a worked example.
Read articleMass Balance in Forced Degradation: Why It Does Not Close
Why mass balance in forced degradation rarely closes: non-chromophoric and volatile degradants, adsorption and response factors, plus how to close the gap.
Read articlePlanning a Forced Degradation Study under ICH Q1A(R2)
Forced degradation study design under ICH Q1A(R2): stressor choice, target degradation, mass balance and stability-indicating methods, with real results.
Read articleICH M7 Classification: Class 1 to 5, by Example
ICH M7 classification explained class by class, with the dual (Q)SAR assessment and five real impurities scored, including NDMA.
Read articleNitrosamine Risk Assessment: An ICH M7 Workflow
A practical nitrosamine risk assessment workflow for NDSRIs: ICH M7 dual assessment, real classifications, and where the QSAR goes out of domain.
Read article
Common questions
How do I identify an unknown impurity by LC-MS?
First determine the molecular formula from accurate mass and isotope pattern, then derive fragments and neutral losses from the MS/MS spectrum and match them against the API, the synthesis route and known degradation pathways. CovaSyn works through these steps systematically and delivers a ranked list of candidates with reasoning.
Who can identify an unknown impurity for us?
We do. In the initial call we go through the peak, substance and data and agree on scope. The report typically arrives within 5 working days once we have your complete data.
When does an impurity have to be identified?
For drug substances and drug products, ICH Q3A and Q3B set reporting, identification and qualification thresholds that depend on the maximum daily dose. Potentially mutagenic impurities additionally fall under ICH M7 with much lower limits. CovaSyn supports identification and classification; which threshold applies to your product is decided by your regulatory expert.
What should I do if mass balance does not close in forced degradation?
Common causes are degradation products without a chromophore, volatile or non-eluting products and different response factors. CovaSyn predicts likely degradation products, searches for them in your MS data and shows where the missing mass most likely is.
How is an identified impurity classified under ICH M7?
First, existing mutagenicity and carcinogenicity data are searched. If there are none, the structure is assessed with two complementary (Q)SAR methodologies, one expert rule-based and one statistical, followed by expert review. CovaSyn provides alerts, prediction and applicability domain as the basis; your qualified expert confirms the classification.
Related problems we solve
Spectra interpretation for NMR, MS, IR and UV/Vis
The spectra have been sitting on the desk for days, and nobody has time to assign them properly.
See solutionExtractables and leachables assessment: identification to toxicology
The extractables study produced a long peak list, and for most peaks we have neither a name nor an assessment.
See solution
Free PDF
Results you can rely on
Our beginner's guide for chemistry, pharma and biotech: how to tell an estimate from a calculation, seven questions to ask of every result and six questions to ask every provider. 8 pages.
Next step
Tell us about your unknown peak.
30 minutes on Microsoft Teams with the CovaSyn team. If it is not a fit, we will say so.