Analytics · Analytics
“The spectra have been sitting on the desk for days, and nobody has time to assign them properly.”
Spectra interpretation for NMR, MS, IR and UV/Vis
Whether structure elucidation, identity testing or assignment for a report: CovaSyn interprets your NMR, MS, IR and UV/Vis data and checks them against the expected structure. You receive an assignment with its reasoning, which your expert reviews and approves.
When you need this
- A new intermediate or by-product needs structural confirmation, and the 2D NMR data have not been assigned yet.
- Incoming goods testing or release needs a traceable identity test by IR or NMR.
- A spectrum does not match the expected structure, and it is unclear whether it is an isomer, a tautomer or an impurity.
- Interpretation ties up experienced people who should be working on methods and projects.
What it costs when the case stays open
- Releases and project decisions wait for data that was measured long ago.
- The one expert who assigns spectra reliably becomes the bottleneck.
- Sloppy assignments only surface in the audit or at the customer.
What you get
Signal assignment
Every relevant signal in NMR, MS, IR or UV/Vis assigned to the structure, with deviations from the predicted spectrum flagged.
Structure proposal or confirmation
For an unknown structure, a ranked list of plausible candidates from formula and spectra; for a known structure, a clear statement whether the data fit.
Purity and foreign signals
Indications of residual solvents and impurities and, where the data support it, a content estimate by qNMR.
Report for review and approval
Input data, predictions and the reasoning behind each assignment are in the report, so your expert can trace every statement.
From an open case to a approved report
1. Discuss the case
30 minutes on Microsoft Teams about the compound, the question and the data. Afterwards you know whether we take on the case and which data we need.
2. Hand over the data
Raw data and context, such as spectra, chromatograms, stability tables and the specification. The report typically arrives within 5 working days once we have your complete data.
3. Review and release
The report states its data basis, calculation path and limits. Review and release happen on your side under your quality system.
What we evaluate for this
Every number is computed and reproducible, predictions state their uncertainty. Every evaluation is documented with its input data and reasoning so your expert can review and sign it off.
NMR: assignment checked against prediction
Signal assignment in 1D and 2D spectra, comparison with the predicted spectrum, structure elucidation and confirmation, purity by qNMR, impurities flagged.
MS: formula and fragments
Molecular formula from accurate mass and isotope pattern, assignment of fragments and neutral losses, comparison with databases.
IR: identity confirmed
Band assignment, identification, check against the expected structure and comparison with reference spectra.
UV/Vis: comparison and content
Interpretation and prediction of UV/Vis spectra, comparison with the expectation and quantification.
Who it is for
For analytical, QC and CMC teams at contract labs, CDMOs, generics manufacturers and specialty chemicals companies, wherever spectra pile up faster than they can be interpreted.
What the computation does not replace
- A prediction does not replace a measurement. The interpretation can only be as good as the signal-to-noise ratio, resolution and sample preparation of the raw data.
- Stereochemistry and closely related isomers often cannot be settled from a single spectrum; in that case we recommend the additional measurement that decides the question.
- Scientific release stays with your responsible person.
Read on
Unknown Impurity Identification by LC-MS/MS
Unknown impurity identification by LC-MS: formula from accurate mass, RDBE, isotope pattern and MS/MS fragment logic, with a worked example.
Read articleUV Dissolution Testing: f2, Sink Conditions, Limits
UV dissolution testing end to end: calibration, ICH Q2(R2) validation, f1/f2 similarity, sink conditions, and where UV loses to HPLC, with a worked example.
Read articleMass Balance in Forced Degradation: Why It Does Not Close
Why mass balance in forced degradation rarely closes: non-chromophoric and volatile degradants, adsorption and response factors, plus how to close the gap.
Read article
Common questions
Who can interpret NMR spectra for us?
We do. In the initial call we go through the question and the data and agree on scope. The report typically arrives within 5 working days once we have your complete data. The same applies to MS, IR and UV/Vis data.
How does structure elucidation from spectra work?
First, accurate mass and isotope pattern narrow down the molecular formula. Then ¹H, ¹³C and 2D NMR establish how the atoms are connected, and IR confirms functional groups. CovaSyn generates candidates, predicts their spectra and ranks them by how well they fit your measured data.
How do I confirm the identity of a substance by IR or NMR?
For identity testing in a GMP environment, comparison with a reference spectrum or a reference substance measured alongside is the standard. A predicted spectrum only serves as a plausibility check in development. CovaSyn matches bands and signals, flags deviations and documents what the identity statement is based on.
What should I do if the NMR spectrum does not match the expected structure?
Check solvent, residual solvents and the water signal first, then isomers, tautomers and by-products. CovaSyn compares the measured spectrum with predictions for these alternatives and shows which explanation the data support best.
Can purity be determined by qNMR?
Yes, if an internal standard was measured alongside and the acquisition parameters suit quantification, such as a sufficiently long relaxation delay. CovaSyn evaluates the integrals and points out signals that may interfere with the result.
Related problems we solve
Identify an unknown impurity by LC-MS
A peak has appeared above the identification threshold, and we do not know what it is.
See solutionExtractables and leachables assessment: identification to toxicology
The extractables study produced a long peak list, and for most peaks we have neither a name nor an assessment.
See solution
Free PDF
Results you can rely on
Our beginner's guide for chemistry, pharma and biotech: how to tell an estimate from a calculation, seven questions to ask of every result and six questions to ask every provider. 8 pages.
Next step
Send us your spectra.
30 minutes on Microsoft Teams with the CovaSyn team. If it is not a fit, we will say so.

