Methods and process · Chromatography
“We need a new HPLC method, and scouting is eating up weeks of instrument time.”
HPLC method development with fewer scouting runs
A new HPLC method often starts with many runs across columns, pH values and gradients. CovaSyn narrows down column, pH and gradient up front from the properties of your analytes, simulates the separation and prepares transfer and validation. Your lab confirms the method with far fewer runs.
When you need this
- A new API or intermediate has no stability-indicating method yet.
- A critical peak pair is not baseline-resolved, and the method needs improving.
- A method has to move to another instrument, another column or another site.
- Validation under ICH Q2(R2) lacks a plan, parameters and acceptance criteria.
What it costs when the case stays open
- Weeks of instrument time go into scouting instead of routine analysis.
- Projects and releases wait until the method is in place.
- A barely robust method fails later in transfer or validation.
What you get
Starting method
A proposal for column chemistry, pH range, organic modifier and gradient, justified by the logD and pKa of your analytes.
Predicted retention and separation
Retention times and a simulated chromatogram, so critical peak pairs become visible before the first run.
Transfer and USP <621>
Converted conditions for other column dimensions or instruments and a check whether the changes stay within the allowed adjustments under USP <621> and Ph. Eur. 2.2.46.
Validation plan
Validation parameters and a draft protocol under ICH Q2(R2), plus system suitability criteria.
From an open case to a approved report
1. Discuss the case
30 minutes on Microsoft Teams about the compound, the question and the data. Afterwards you know whether we take on the case and which data we need.
2. Hand over the data
Raw data and context, such as spectra, chromatograms, stability tables and the specification. The report typically arrives within 5 working days once we have your complete data.
3. Review and release
The report states its data basis, calculation path and limits. Review and release happen on your side under your quality system.
What we evaluate for this
Every number is computed and reproducible, predictions state their uncertainty. Every evaluation is documented with its input data and reasoning so your expert can review and sign it off.
Chromatography: starting method to validation plan
Column selection and equivalent columns, method suggestion with scouting plan, retention time prediction and simulation, transfer and scaling, USP <621> check, system suitability, validation parameters and draft protocol, plus greenness and cost of the method.
pKa and analyte profile
pKa values and a physicochemical profile, from which pH-dependent retention behaviour follows.
Structure and properties checked
Structure, logP and functional groups checked so method planning starts from the correct structure.
Who it is for
For analytical, QC and CMC teams at contract labs, CDMOs, generics manufacturers and specialty chemicals companies, wherever method development and transfer tie up instrument time and experts.
What the computation does not replace
- A prediction does not replace a measurement. Your lab confirms retention times and selectivity for critical pairs, as well as the influence of column batch and instrument.
- Matrix effects, unknown impurities and interactions with excipients are only covered as far as the structures are known.
Read on
HPLC Column Selection and Method Scouting
HPLC column selection chart and decision tree: match C18, phenyl-hexyl, PFP, HILIC or mixed-mode to logD and pKa. Scout fewer columns, start here.
Read articleRetention Time Prediction in HPLC Method Development
What retention time prediction in HPLC is actually good for, what it is not, and a worked impurity panel with real predictions.
Read articleDesign Space, NOR and PAR: ICH Q8 Explained
ICH Q8 design space, NOR and PAR defined precisely, with real worked results showing what a tighter spec costs you in operating window.
Read articleGreen Solvent Substitution Without Losing Solubility
Green solvent replacement in pharma: rank ICH Q3C Class 3 alternatives to DCM and chloroform by predicted solubility before you book lab time.
Read article
Common questions
How do I choose the right HPLC column for my method?
Polarity and ionisation of the analytes decide: logD and pKa show at which pH they are retained sufficiently and which stationary phase gives selectivity. As a rule of thumb, work at least 2 pH units away from the pKa so small pH variations do not shift retention. CovaSyn computes these values from structure and suggests suitable columns and alternatives.
Can HPLC retention times be predicted?
Yes, well enough to compare columns and gradients and spot critical pairs early. The method itself still needs measurements, because column batch, instrument and matrix shift the values.
Which changes to an HPLC method are allowed under USP <621>?
For pharmacopoeial methods, USP <621> allows adjustments within defined limits to parameters such as column length, particle size, flow rate and column temperature, and to the gradient only under additional conditions; system suitability must still be met. CovaSyn converts the adjusted conditions and checks whether they stay within those limits.
Who can develop an HPLC method for us?
We do. In the initial call we go through analytes, goal and instruments and agree on scope. The starting method and report typically arrive within 5 working days once we have your complete data. Your lab runs the confirmation.
What does HPLC method validation include?
Under ICH Q2(R2), depending on purpose, specificity or selectivity, range with calibration model, accuracy, precision, and detection and quantitation limits. Robustness is demonstrated during development under ICH Q14. CovaSyn compiles the relevant parameters and drafts a protocol that your expert adapts and approves.
Related problems we solve
Analytical method transfer and validation for HPLC
The method runs at the sponsor's site, but in our lab the peaks no longer separate, and the original column is discontinued.
See solutionProcess optimization and process capability (Cpk, Ppk)
Our Cpk is too tight, and we don't know which parameter drives the variation.
See solution
Free PDF
Results you can rely on
Our beginner's guide for chemistry, pharma and biotech: how to tell an estimate from a calculation, seven questions to ask of every result and six questions to ask every provider. 8 pages.
Next step
Tell us about your separation problem.
30 minutes on Microsoft Teams with the CovaSyn team. If it is not a fit, we will say so.